Immunoassays are critical tools in the development of monoclonal antibody (mAb) therapeutics, especially during preclinical pharmacokinetics (PK) studies. Traditional enzyme-linked immunosorbent assay (ELISA) techniques, while widely used, present several challenges that can hinder efficiency, accuracy, and overall productivity in the laboratory.
As scientists and R&D directors seeking to optimize your workflows, understanding these challenges and exploring innovative solutions is paramount. This article delves into the common obstacles associated with ELISA in immunoassay workflows and highlights how microfluidic technology can revolutionize these processes.
5 Common Challenges in Immunoassay Workflows During Preclinical PK Studies
- Sample Volume Requirements: ELISAs typically require significant sample volumes1 or high dilutions, which can be problematic when dealing with small or precious samples, such as those from mouse models in preclinical studies. High sample volume requirements not only limit the number of tests that can be performed but also increase the consumption of valuable reagents.
- Manual Pipetting and Workflows: Manual pipetting is a time-consuming and error-prone process. ELISAs often involve multiple pipetting and manipulation steps, including sample dilution, reagent addition, and plate washing. These steps are labor-intensive and can introduce variability, impacting the reproducibility and reliability of results. Technicians frequently spend long hours at the bench, manually handling samples for assays that can last up to four hours.
- Matrix Interference: Non-specific binding and background interference from complex biological matrices are significant issues in ELISA. Components in the samples can bind non-specifically to the assay surfaces, leading to high background signals that obscure the detection of the target analyte. This interference can compromise data quality and necessitate additional steps to mitigate its effects.
- Slow Assay Speed: ELISA procedures are notoriously slow, often requiring long incubation times to achieve sufficient binding between the antigen and antibody. These lengthy processes can delay the generation of critical data needed for decision-making in drug development.
- Low Throughput: The traditional ELISA format, typically conducted in 96-well plates, limits throughput. Processing a large number of samples in parallel is challenging, which can slow down the pace of research and development, especially in high-demand environments.
5 Ways that Microfluidic Technology Can Simplify and Automate Immunoassay Workflows2,3
Microfluidic technology represents a significant advancement in immunoassay workflows, offering a robust solution to the limitations of traditional ELISA methods. One innovative approach leveraging miniaturized fluidic channels, automated processes utilizing capillary action, and centrifugal forces with a disk-based labware automatically performs highly efficient and precise assays. (Watch a 1-minute video of how the Gyrolab Bioaffy CD exemplifies this approach.)
Here’s how this microfluidic technology compares to ELISA and the advantages it presents:
- Automation and Time Savings: Unlike the labor-intensive steps of ELISA, microfluidic technology automates the immunoassay process, dramatically reducing the need for manual intervention. This automation minimizes human error, increases efficiency, and allows scientists to focus on more critical tasks. Traditional ELISA assays often take several hours due to multiple incubation and washing steps. In contrast, microfluidic systems can complete an entire assay in about an hour, facilitating rapid data generation and quicker decision-making.
- Low Sample Volume: One of the most significant advantages of microfluidic technology is its ability to perform assays with very low sample volumes. Traditional ELISA often requires larger volumes, which can be a challenge when working with limited or precious samples, such as those from mouse models or specific biological fluids like cerebrospinal fluid. Microfluidic systems can operate with as little as 5-10 µL of sample, allowing for multiple analyses from a single sample source. This efficiency is particularly beneficial in preclinical studies where conserving samples is critical.
- Reduced Background Interference: Microfluidic systems with flow-through immunoassay design significantly reduce background noise and non-specific binding, a common issue with ELISA. In traditional plate-based assays, prolonged incubation times can lead to non-specific binding and higher background signals, complicating data interpretation. Microfluidic technology uses short interaction times—typically around 6 seconds—for samples to flow over affinity columns, minimizing the potential for non-specific binding and reducing background interference. This results in cleaner, more robust data.
- High Throughput and Reproducibility: Traditional ELISA methods, often limited by the 96-well plate format, can struggle with high throughput requirements, especially in large-scale studies. Microfluidic systems, however, are designed for high throughput, with the ability to process numerous samples simultaneously. This capability enhances lab productivity, enabling the rapid processing of large sample sets. Moreover, the precision of microfluidic systems ensures high reproducibility across assays, providing consistent and reliable data essential for drug development.
- Sensitivity and Dynamic Range: Microfluidic technology typically offers superior sensitivity and a broader dynamic range compared to ELISA. This is crucial for accurately quantifying a wide range of analyte concentrations. The enhanced sensitivity and dynamic range ensure that critical data points are not missed, and more detailed insights into the biological processes under study can be obtained.
Conclusion
The challenges posed by traditional ELISA methods in immunoassay workflows are significant but not insurmountable. By leveraging advanced microfluidic technology, the Gyrolab® platform addresses these pain points, offering automation, efficiency, and precision. This transformation not only enhances lab productivity but also accelerates the journey from preclinical studies to therapeutic breakthroughs.
Ready to Explore Further?
If you’re looking to overcome the limitations of traditional ELISA and enhance your immunoassay workflows, it’s time to explore the Gyrolab platform. This groundbreaking technology automates immunoassays at the nanoliter scale, utilizing microfluidics for efficient workflows and high-quality data. The Gyrolab suite, including the Gyrolab xPand and Gyrolab xPlore systems, Bioaffy CDs, kits and solutions, and custom assay services, empowers scientists to maximize productivity and make data-driven decisions swiftly.
Gyrolab technology offers:
- Miniaturized ELISA technology for automated nanoliter-scale immunoassays
- Unattended operation capabilities, requiring minimal sample and reagent consumption
- High reproducibility and broad dynamic ranges
- Shortened run times to about an hour with fully unattended automation
- Simplified workflows with no required incubations, unlike traditional ELISAs
With over 20 years of industry leadership and global trust from pharma, biotech, and CROs, Gyros Protein Technologies is dedicated to accelerating breakthroughs in drug development. Our technology not only saves time and resources but also delivers reliable, high-quality data to support your research and development efforts.
References
- Patkar R, Wai C, et al. Chapter 6 - Laboratory skills for immunologists: utility and limitations with emphasis on allergy research. 2022. Allergic and Immunologic Diseases. 2022 Oct: 145-186. https://doi.org/10.1016/B978-0-323-95061-9.00006-0
- Goodman J, Agoram B. Analytical assay platforms for soluble target engagement biomarkers: old favorites and emerging technologies. Bioanalysis. 2013 Dec;5(23):2919-31. doi: 10.4155/bio.13.262. PMID: 24295118.
- Allinson JL. Automated immunoassay equipment platforms for analytical support of pharmaceutical and biopharmaceutical development. Bioanalysis. 2011 Dec;3(24):2803-16. doi: 10.4155/bio.11.209. PMID: 22185280.